Candlelux CKS-2A/DS Double Sided LED Keluar Sign 3-Hour Backup Slim Surface Type (543mm) Excellent Certified & Premium

The Candlelux CKS-2A/DS Slim Type LED Keluar Sign is a premium, double-sided, maintained emergency exit lighting solution featuring integrated directional arrows for multi-way visibility. Utilizing 20 energy-saving LEDs, a robust frosted green die-cast aluminum frame, and a highly reliable 3.6V Nickel-cadmium battery, it delivers up to 3 hours of critical directional illumination during sudden power outages. Fully certified by SIRIM and Jabatan Bomba to meet all core Malaysia Standards, this slim-profile surface mounted sign provides seamless building compliance and unwavering safety.

Share:

Description

Candlelux CKS-2A/DS Double Sided LED Keluar Sign 3-Hour Backup Slim Surface Type (543mm) Excellent Certified & Premium

Ensure ultimate commercial property safety and strict regulatory compliance with the Candlelux CKS-2A/DS Slim Type LED Self-Contained Emergency Keluar Sign.

Expertly engineered for maximum visibility and high energy efficiency, this premium double-sided safety sign is a mandatory requirement for high-traffic corridors, escape routes, shopping malls, corporate offices, and public institutions.

Operating on a continuous maintained mode, the directional fixture remains illuminated constantly under regular building power and switches seamlessly to active internal battery supply during unforeseen power failures.

The CKS-2A/DS is equipped with a highly efficient light array comprising 20pcs x 0.065W LEDs, projecting clear, bright, and uniform illumination across both faces to guide occupants effectively from multiple directions.

Powering this system is a high-grade 3.6V 1000mAh Nickel-cadmium battery, supplying a dependable 3-hour backup duration during critical building emergencies.

Built with sophisticated environments in mind, the body boasts a sleek, architectural die-cast aluminum casing finished in frosted green, paired perfectly with a high-transmittance acrylic plate containing directional arrow markings.

Designed to perform reliably across ambient operational temperatures from 0°C to 60°C and weighing a solid ±0.9kg with a width profile of 543mm, its surface mounting design guarantees stable ceiling or wall installation.

Official building code pass-offs are fully guaranteed through rigorous manufacturing standards.

The Candlelux CKS-2A/DS is thoroughly certified by SIRIM QAS International Sdn. Bhd. and approved by Jabatan Bomba dan Penyelamat Malaysia.

It completely satisfies the legal protocols of Malaysia Standards MS-983:2004, MS-619-2-22:2005, and MS IEC 60598-1:2012 with an IP20 protection level.

Routine maintenance checks are streamlined with an embedded red LED charging mode indicator and an integrated manual push-test switch to instantly simulate a grid blackout.

Backed by an exceptional 5-year warranty on components and a 1-year warranty on the battery, it delivers ultimate long-term structural value and life-saving security.

Product Details

  • Brand & Model : Candlelux EL & KS CKS-2A/DS (SLIM TYPE)
  • Product Type : LED Self-Contained Emergency Keluar Sign (Double Sided with Arrow)
  • Mode of Operation : Maintained
  • Input Voltage : 240V ± 10%, 50/60Hz
  • Lamp Type : 20pcs x 0.065W LED
  • Battery Specifications : 3.6V, 1000mAh Nickel-cadmium Battery
  • Backup Duration : 3 Hours
  • Charger Type : Constant Current
  • Operating Temperature : 0°C to 60°C
  • Status Indication : Red LED “On” (Charging Mode) / Push Test-Switch (Simulate Power Failure)
  • Fitting Construction : Die-cast Aluminum Casing in Frosted Green with Acrylic Plate
  • Dimensions (L x W x H) : 543mm x 24mm x 194mm (146mm Plate + 48mm Frame)
  • Dimension Tolerance : ±0.03mm
  • Weight : ±0.9kg
  • IP Rating : IP20
  • Certified Compliance : Malaysia Standards MS-983:2004, MS-619-2-22:2005, MS IEC 60598-1:2012
  • Approved By : SIRIM QAS International Sdn. Bhd. & Jabatan Bomba dan Penyelamat Malaysia
  • Application Type : Surface Mounting

Common FAQs for Candlelux EL & KS CKS-2A/DS

Q1: What makes the CKS-2A/DS model different from a standard exit sign?

A: The CKS-2A/DS is a Double-Sided exit sign equipped with directional arrows. This allows the “KELUAR” lettering and escape route graphics to be viewed clearly from both directions, making it ideal for perpendicular hanging installations in long corridors, intersections, or large open hall spaces.

Q2: What does “Maintained” operation mean for this double-sided sign?

A: Maintained operation means the sign stays illuminated continuously using grid power during standard building operations to serve as a daily directional exit marker. If the building suffers a power blackout, the fixture instantly draws power from its internal battery to maintain visibility.

Q3: Is the CKS-2A/DS fully certified to pass Malaysian fire safety inspections?

A: Yes, absolutely. The fixture is fully certified by SIRIM QAS International and approved by Jabatan Bomba dan Penyelamat Malaysia. It holds full certification under MS-983:2004, MS-619-2-22:2005, and MS IEC 60598-1:2012, making it completely compliant for local building handovers.

Q4: How do building managers conduct required regular diagnostic testing?

A: The fixture includes an integrated manual Push Test-Switch located directly on the die-cast aluminum chassis. Pressing this switch breaks the mains connection to simulate an instant power grid failure, allowing you to quickly verify the battery discharge status and LED illumination. A Red LED stays “On” during normal power conditions to confirm the battery is charging correctly.

Q5: What is the warranty term for this model?

A: Candlelux offers an industry-leading warranty for this emergency unit: a 5-year warranty on core electronic components and a 1-year warranty on the Nickel-cadmium battery pack (terms and conditions apply)