JM Recess Emergency Keluar Sign TR218C/R Maintained SMD LED Ceiling Recessed Commercial Premier

The JM Recess Emergency Keluar Sign (TR218C/R) is a SIRIM and BOMBA approved maintained LED emergency exit sign designed for sleek wall or ceiling recessed mounting. Featuring 16 x 0.2W SMD LEDs, a sealed Nickel-Cadmium battery providing over 3 hours of emergency power, and low-voltage over-discharge protection, it delivers dependable, energy-efficient safety illumination fully compliant with Uniform Building By-Law Regulations in Malaysia

Share:

Description

JM Recess Emergency Keluar Sign TR218C/R Maintained SMD LED Ceiling Recessed Commercial Premier

Ensure full life-safety compliance and seamless architectural integration with the JM Recess Emergency Keluar Sign (TR218C/R).

Purpose-built for commercial shopping malls, hospitals, office towers, and public institutions, this recessed exit sign provides clear, high-visibility guidance during normal building operations and unexpected emergency power outages.

Operating in a continuous Maintained mode, the TR218C/R features an energy-efficient array of 16 x 0.2W SMD LEDs that illuminate consistently whether AC mains power is active or offline.

The system operates on standard 240V ±10% 50Hz input voltage with low power consumption under 6.3VA.

During a power loss, a high-performance Sealed Nickel-Cadmium Battery instantly takes over, providing reliable illumination for more than 3 hours.

Built-in low voltage cut-off protection safeguards the battery against over-discharge, prolonging its overall service life. A bright red LED indicator gives clear visual confirmation of active battery charging.

Constructed with a heavy-duty metal casing finished in protective epoxy powder coating, the unit features a ceiling/wall recessed profile (620mm L x 82mm W) designed to sit flush for a refined modern aesthetic.

Available in both Single-Sided (TR218C/R) and Double-Sided (TR218C/RD) pictogram configurations, it accommodates varied exit route directions.

Fully certified under MS 983:2004, MS 619-2-22:2012, and MS IEC 60598-1:2012 standards, the sign holds full SIRIM licensing, BOMBA Fire Department approval, and approval by the Chief Electrical Inspector of Malaysia, fully complying with Uniform Building By-Law Regulations.

Supported by a 1-year manufacturer warranty, this recessed exit light offers long-term reliability for demanding building requirements.

Product Details

  • Brand : JM
  • Model Number : TR218C/R
  • Product Category : Recess Emergency Keluar Sign / Exit Sign
  • Mode of Operation : Maintained
  • Input Voltage : 240V ±10%, 50Hz
  • Power Consumption : < 6.3VA
  • Lamp Type / Light Source : SMD LED (16 x 0.2W SMD LED)
  • Lamp Status (Mains ON / OFF) : 16 x 0.2W SMD LED / 16 x 0.2W SMD LED
  • Battery Type : Rechargeable Sealed Nickel-Cadmium Battery
  • Rated Emergency Duration : > 3 Hours
  • Housing & Finish : Metal Casing Finished in Epoxy Powder Coating
  • Charging Monitor : Red LED Indicator (Indicates Battery Charging)
  • Projection / IP Rating : IP20
  • Safety Feature : Low Voltage Cut-off to Prevent Battery Over Discharge
  • Mounting Type : Wall or Ceiling Recessed Mounting
  • Certified Compliance : MS 983:2004 | MS 619-2-22:2012 | MS IEC 60598-1:2012 | BOMBA Approved
  • Warranty : 1 Year from Date of Delivery
  • Main Sign Dimensions : 538 mm (L) x 198 mm (W) x 125 mm (H)
  • Recess Cutout / Recess Box D1 : 540 mm (L) x 40 mm (W) x 55 mm (H)
  • Recess Outer Flange D2 : 620 mm (L) x 82 mm (W)
  • Product Net Weight : 1.3 kg
  • Inner / Outer Box Sizes : Inner: 625 x 205 x 82 mm | Outer: 640 x 43 x 22 mm
  • Pictogram Options : Single Sided & Double Sided (TR218C/R & TR218C/RD variants)

Common Product FAQs

Q: Is the BSLight TR218C/R certified for Malaysian building codes and fire safety?

A: Yes. It is BOMBA Approved, quality assured by full SIRIM License, approved by the Chief Electrical Inspector of Malaysia, and complies fully with Uniform Building By-Law Regulations as well as standards MS 983:2004, MS 619-2-22:2012, and MS IEC 60598-1:2012.

Q: What is the difference between Maintained mode and Non-Maintained mode?

A: The TR218C/R operates in Maintained mode, meaning the LEDs stay continuously illuminated under normal mains power and automatically switch to battery operation during a power outage.

Q: How long will the exit light stay lit during a power outage?

A: It provides a rated emergency illumination duration of over 3 hours (>3 Hours) powered by its internal Sealed Nickel-Cadmium battery.

Q: What mounting method does the TR218C/R require?

A: The TR218C/R is designed for recessed wall or ceiling mounting into ceiling soffits or drywall enclosures.

Q: Does the fixture prevent battery damage from total discharge?

A: Yes, it features a built-in Low Voltage Cut-off safety protection system that automatically cuts power off before the battery completely drains, preventing permanent damage.

Reviews

There are no reviews yet.

Be the first to review “JM Recess Emergency Keluar Sign TR218C/R Maintained SMD LED Ceiling Recessed Commercial Premier”

Your email address will not be published. Required fields are marked *